Local time signature cannot be written.
Reported version
3.4
Type
Graphical (UI)
Frequency
Once
Severity
S4 - Minor
Reproducibility
Always
Status
by design
Regression
No
Workaround
No
Project
- Open random score with multiple staves.
- Press ctrl to add local time signature on one of those staves.
A notification "Cannot change local time signature: Measure is not empty" even though the bar is. This problem can't be solved by reopen the software or reboot the comcuter or even reset.
Comments
score needed, likely the measure indeed isn't empty
And update to 3.6 and test there too
In reply to And update to 3.6 and test… by Jojo-Schmitz
Tried and it failed again
None of the parts is empty, so the error message is correct
In reply to None of the parts is empty,… by Jojo-Schmitz
Here's the copy of above score. I've delete everything I can except the 2/4 local time signature on oboe and English Horn at bar 107 since I can't. It will show the same message when trying to delete them, and that is the only local time signature I managed to add.
In reply to None of the parts is empty,… by Jojo-Schmitz
Problem solved. I just deleted all the separate parts and it worked. Sorry for taking your time