Partial measure copy/paste broken (0.9.6 regression)
Steps to reproduce bug
1. Create a new score for piano in 4/4 time
2. Add two notes to the treble staff, measure 1
3. Add two notes to the bass staff, measure 1
4. Select all four notes
5. Edit > Copy
6. Click on measure 2
7. Edit > Paste
Expected behavior: Measure 2 should look identical to measure 1
Actual behavior: Measure 2 is missing the last beats of the measure
MuseScore version: r.2605
(Operating System: Windows XP)
First reported by REdwards: http://www.musescore.org/en/node/3980
Comments
Seems to be fixed. (Tested using r. 2636 nightly, Windows XP)
Automatically closed -- issue fixed for 2 weeks with no activity.