Fingering: automatic placement wrongly positions voice 2 LH guitar fingering
Reported version
3.0
Type
Functional
Frequency
Once
Severity
S3 - Major
Reproducibility
Always
Status
closed
Regression
No
Workaround
No
Project
OS: Windows 10 (10.0), Arch.: x86_64, MuseScore version (64-bit): 3.0.0.4095, revision: 5859662
Open the attached score. LH Guitar Fingering has been added from the palette.
Result: Voice 1 fingering positions are as expected. But most of the the fingering symbols for voice 2 have been wrongly placed, colliding with note stems.
This also affects imported 2.x scores when the reset option is taken: LH Guitar fingering is OK in voice 1 but wrongly positioned in voice 2.
Attachment | Size |
---|---|
fingering_1.mscz | 7.44 KB |
Comments
Resubmitted. See #279241: Fingering: automatic placement wrongly positions LH Guitar Fingering.