MuseScore1.1 build 4611: Voltas do not work correctly
Voltas do not work correctly when the first volta is expected to play twice and the second volta the third time.
Test 1:
Method: The first volta is given a repeat list of 1,2 and the second volta a repeat list of 3.
Result: the first volta repeats once then plays the second volta.
Test 2:
Method: The first volta is given a repeat list of 1,2,3 and the second volta a repeat list of 4.
Result: the first volta repeats once then plays the second volta (no change from Test 1).
See attached test files.
Attachment | Size |
---|---|
volta test 1.mscz | 1.8 KB |
volta test 2.mscz | 1.73 KB |
Comments
I believe this is not a bug. You need to change the number of repeats for the last measure before the close repeat to 3. Not very intuitive, but works that way
It is true that fixes the repeats. I would expect setting the volta to adjust that if necessary. I didn't know of it. I didn't see it in the documentation.
Thinking about this, how would setting measure repeats work if the volta had an unusual repeat pattern such as 1,3,4,6?
simple: it won't... :-)
How about the trunk?
If there's no existing report, you can create one.
I think we should close this?