Create irregular measures from second measure and followings results in corruption
Reported version
3.0
Priority
P0 - Critical
Type
Functional
Frequency
Once
Severity
S2 - Critical
Reproducibility
Always
Status
closed
Regression
Yes
Workaround
No
Project
OS: Windows 10 (10.0), Arch.: x86_64, MuseScore version (64-bit): 3.0.1.4922, revision: 598057d
1) Grand staff template
2) Select whole rest measure 2→ Type 6 (to get two half rests)
3) Ctrl + Del (for timewise delete)
4) Save/Exit/Reload
Result : corruption (Expected 2/4, Found 1919/1920)
Here the test file (with step#2 repeated in measure 4): Irregular.mscz
Fix version
3.0.1
Comments
From what I see, might be a side effect of this commit: https://github.com/musescore/MuseScore/commit/3db34aa4718f7ce55cd71395f…
To fix a related issue: #280574: Corruption when deleting and selecting beats with two instruments
See https://github.com/musescore/MuseScore/pull/4548.
Fixed in branch master, commit 9ea575d004
fix #281321: Create irregular measures from second measure and followings results in corruption
Fixed in branch master, commit 6d522eedb1
Merge pull request #4548 from mattmcclinch/281321-time-delete
fix #281321: Create irregular measures from second measure and following results in corruption
Automatically closed -- issue fixed for 2 weeks with no activity.