Copying a partial measure leaves rest(s) missing in voices 2-4
Reported version
3.4
Type
Functional
Frequency
Once
Severity
S4 - Minor
Reproducibility
Always
Status
closed
Regression
Yes
Workaround
Yes
Project
OS: Windows 10 (10.0), Arch.: x86_64, MuseScore version (64-bit): 3.4.2.9788, revision: 148e43f
Open the attached file. Shift select the first two 1/4 notes, copy, then paste in the next bar.
Expected result: Appropriate rests should be added to all voices.
Actual result: Rest(s) missing in voice 2.
This worked in MS 2.3.2.
Attachment | Size |
---|---|
copy_partial_measure.mscz | 5.3 KB |
Comments
See https://github.com/musescore/MuseScore/pull/5702.
For 3.x see https://github.com/musescore/MuseScore/pull/7871
Fixed in branch 3.x, commit 1b26c4c192
_Fix #301016: Copying a partial measure leaves rest(s) missing in voices 2-4.
Resolves: https://musescore.org/en/node/301016
Backport of #5702_
For master see https://github.com/musescore/MuseScore/pull/7932 (rebased version of https://github.com/musescore/MuseScore/pull/5702)
Fixed in branch master, commit f2092fa931
_Fix #301016: Copying a partial measure leaves rest(s) missing in voices 2-4
Resolves: https://musescore.org/en/node/301016.
Rebased version of #5702_
Automatically closed -- issue fixed for 2 weeks with no activity.